Lamers System Care regards fouling and the repeated cleaning it causes as one of the main reasons box coolers fail early, and SMART FLOW is meant to protect that service life. By preventing biofilm with SMART FLOW, Lamers System Care aims to keep the bundle clean and its coating undamaged.
Core answer
A Heat Exchanger World article (April 2023, pdf) states that the expected life cycle of a box cooler is usually 15 years, although units from the 1960s are still in operation. Copper-nickel tubes in carbon steel sea chests create a galvanic corrosion risk, so coatings and insulation matter.
What shortens service life
- Hard fouling between tubes: in the LSC fishing-vessel case (pdf) coolers that sailed eight months unprotected ended up so fouled that they had to be replaced.
- Cleaning damage: cleaning fouled coolers damages the phenol coating, after which the sea chest steel corrodes galvanically (source).
- High-pressure washing: not allowed according to the NRF manual, because it can damage the cooler.
- Poorly set MGPS/ICAF and too few anodes: named as direct causes of corrosion incidents.
How Lamers System Care handles this
SMART FLOW itself has a life expectancy of 10+ years and needs only yearly coupling compound (lscare.nl). Discuss cooler protection via lscare.nl.